Maintenance Cycle Table


Item


Standard Cycle


Key Indicators


Air Pressure Test


Weekly


Fluctuation ≤ 0.05 MPa


Friction Pad Wear


Quarterly


Limited Thickness 5mm


Airbag Aging Inspection


Annual


Crack Depth < 1mm


Fault Tree Analysis


Noise Issue → Insufficient Air Pressure (65%) / Misalignment (25%) / Friction Pad Oil Contamination (10%)